Notice: Function WP_Scripts::add was called incorrectly. The script with the handle "elementor-frontend" was enqueued with dependencies that are not registered: jquery-ui-position. Please see Debugging in WordPress for more information. (This message was added in version 6.9.1.) in /home/u918277800/domains/ownersmanual.store/public_html/wp-includes/functions.php on line 6131

Owner Manuals

Peugeot Boxer 2006-2014 Owner's Manual Quick Help Battery

131QUICK HELP 8 Discharged battery A. Positive metal point on your vehicle B. Slave battery C. Earth on your vehicle Starting from another battery - Connect the red cable to the metal point A then to the positive (+) terminal of the slave battery B . - Connect one end of the green or black cable to the negative (-) terminal of the slave battery B . - Connect the other end of the green or black cable to the earth point C on your vehicle. - Operate the starter, let the engine run. - Wait for the engine to return to idle, then disconnect the cables. Charging the battery using a charger - Go to the battery located in the front left floor. - Disconnect the battery. - Follow the instructions for use given by the battery charger manufacturer. - Reconnect starting with the negative (-) terminal. - Check that the terminals and connectors are clean. If they are covered with sulphate (white or greenish deposit), disconnect them and clean them. BATTERY
132 Discharged battery The charging operation must be carried out in a ventilated area away from naked flames or any possible sources of sparks to eliminate the risk of explosion and fire. Do not attempt to charge a frozen battery: it must first be thawed to eliminate the risks of explosion. If the battery has frozen, before charging it have it checked by a specialist who will check that the internal components have not been damaged and that the container is not cracked, which could mean that there is a risk of a leak of toxic and corrosive acid. Proceed with a slow charge charge at low current for a maximum pf about 24 hours to avoid damaging the battery. The batteries contain harmful substances such as sulphuric acid and lead. They must be discarded in accordance with the provisions of the law and must not, in any circumstances, be discarded with household waste. Take used batteries to a special collection point. Before disconnecting the battery, you must wait for 2 minutes after switching off the ignition. Never disconnect a terminal when the engine is running. Never charge a battery without first disconnecting the terminals. Close the windows and doors before disconnecting the battery. After every reconnection of the battery, switch on the ignition and wait 1 minute before starting to allow the electronic systems to be initialised. If slight difficulties are experienced after this, please contact a PEUGEOT dealer or a qualified workshop. Unscrew the 6 access cover retaining screws. Lift off or remove completely the access cover. Press lever 1 downwards to spread the clamp. Remove the terminal 2 from the negative (-) post. Access to the battery
133QUICK HELP 8 Discharged battery The presence of this label, in particular with the Stop & Start system, indicates the use of a 12 V lead-acid battery with special technology and specification; the involvement of a PEUGEOT dealer or a qualified workshop is essential when replacing or disconnecting the battery. Failure to observe this recommendation may cause premature wear of the battery. After refitting the battery by a PEUGEOT dealer or a qualified workshop, the Stop & Start system will only be active after a continuous period of immobilisation of the vehicle, a period which depends on the climatic conditions and the state of charge of the battery (up to about 8 hours). Do not disconnect the battery to charge it. It is advisable to disconnect the negative (-) terminal of the battery if the vehicle is not to be used for a period of more than one month. The description of the battery charging procedure is given as an indication only. If the battery has been disconnected for some time, it may be necessary to reinitialise the following functions: - the display parameters (date, time, language, distance unit and temperature unit), - the radio stations, - the central locking. Some settings are cleared and must be reprogrammed, consult a PEUGEOT. If your vehicle is fitted with a tachograph or an alarm, disconnection of the negative (-) terminal of the battery (located under the floor on the left-hand side, in the cab) is recommended if the vehicle is not to be used for a period of more than 5 days.
Scroll to Top

Notice: Function WP_Scripts::add was called incorrectly. The script with the handle "elementor-pro-frontend" was enqueued with dependencies that are not registered: elementor-pro-webpack-runtime. Please see Debugging in WordPress for more information. (This message was added in version 6.9.1.) in /home/u918277800/domains/ownersmanual.store/public_html/wp-includes/functions.php on line 6131